• Left click on Operation to open the next screen.
• If this is a single unit, the RS485 Termination should be selected for ON. Notice that there is
only one Unit shown. If multiple units are installed, each one is listed on it’s own line.
• Selecting a Unit , permits editing the configuration, deleting the configuration, turning the
RS485 termination On or Off, or Operates the unit.
• When the units are installed with the RS485 lines to multiple units, the unit connected to the
end plug in the cabling MUST have it’s termination ON, and all other units MUST have their
terminations OFF.
• Select the unit to control, and left click Operate.
15