Monroe-electronics R199 Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Czujniki Monroe-electronics R199. Monroe Electronics R199 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 29
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Series3000
Model R-199
ProgramTimer4
Audio/VideoRelayPanel
WithEthernetInterface
Instruction Manual
CATV Switchingand Control
EAS
585-765-2254 fax 585-765-9330
100HouselAve.|Lyndonville|NY|14098
www.monroe-electronics.com
PrintedinUSA
Copyright
MonroeElectronics,Inc.
Specifications subject tochange without notice
P/N1340230
04/16/14
Przeglądanie stron 0
1 2 3 4 5 6 ... 28 29

Podsumowanie treści

Strona 1 - Instruction Manual

Series3000Model R-199ProgramTimer4Audio/VideoRelayPanelWithEthernetInterfaceInstruction ManualCATV Switchingand ControlEAS585-765-2254 

Strona 2 - Table of Contents

Whenthebuttonisreleased,allrelayswillbeoff.Thentheunitwillbeginwaitingforacom-mand.OnceyouhavesettheIPaddressforyourunit,

Strona 3 - Specifications

SET UP INSTRUCTIONSTosettheparametersintheR199,clickon‘Setup/Control’,enterthepassword(r199set),11andthefollowingscreenwillappear:

Strona 4 - GENERAL DESCRIPTION

Ifweselect‘Password’,thefollowingscreenappears:OnlyonepasswordisusedfortheR199.ThedefaultpasswordfortheR199isr199set,alllowerc

Strona 5 - SectionView

Afterclicking‘Save’,thefollowingscreenappears:AnychangesyouhavemadetotheSetup/Controlpasswordhavebeensaved.Ifweselect‘Label’13Weh

Strona 6 - General Instructions

Ournextsettingwouldbe‘Time’14First,setyourtimezoneusing“ChangeTimeZone”.Then,ifyour‘ComputerClock’isaccurate,selectthisoptiona

Strona 7 - GENERAL SWITCHING

15IftheautomaticsynchronizationisOn,theR199willusetheNTPserverintheboxtosynchro-nizeitstimeatmidnighteverydayEntertheNTPser

Strona 8

Program list :ProgramDescriptionRelay R1/R2/R3/R4forRelay/SwitchState Pri(mary)/Sec(ondary)DayofWeek/DateTimeHH:MM Hour:Minutetheprogram

Strona 9 - ETHERNET INTERFACE SETUP

17ProgrammingtheR199isstraightforward.Therearetwotypesofevents:Aweeklyevent,thatwillrepeateachweekatthesametimeandday.Andda

Strona 10

18Toprogramaweeklyevent,clickon‘AddNewProgram’,andthefollowingscreenwillappear.Selectthe‘ProgramName’andthe‘SwitchState,andthe

Strona 11 - SET UP INSTRUCTIONS

19Oncefinishedwiththisentry,click‘Submit’andappears.[WehaveenteredaprogramforM-Fat12:00.]Theprogramisimmediatelyactive.Youmust

Strona 12

Table of ContentsSpecifications 3General Description 4General Instructions 6Applications General Switching 7 Connections 8 Ethernet Interface Se

Strona 13

20Oncetheweeklyeventsareentered,wewouldenterany‘Dated’events.Whenenteringthese,ensurethatnoticeistakenofweeklyeventsthatmight

Strona 14

Nowclickon‘Addnewprogram’(ortherelayyouareprogramming),andthefollowingscreenappears.Enterthe‘ProgramName’,the‘SwitchAction’,the

Strona 15

ChangingtheIPaddressmaybedoneinthe‘Network’screen.Itisstraightforwardasisshowninthescreenbelow,andwhenfinished,clicking‘Save’

Strona 16

23EnablingemailnotificationsforselectedhappeningsintheR199isdoneonthispage.YoumustknowyourSMTPServerName,andtheother*entries.F

Strona 18

25OncesettingupalltheparametersintheR199,selectingHome/LogOutwillsendyoutothispage.NotethatifyoudonotLogOutwhendone,theunith

Strona 19

26SelectingtheMonitorbuttononthe‘FrontPage”ofthescreenbringsyouhere.Itallowyoutoviewrelaystatus,anxtprogramstatus.Itispossible

Strona 20

ThispageallowsrealtimecontroloftherelaysintheR199.ClickontheLED’stoactivateordeactivatetheindividualrelays.27Selecting‘Control’

Strona 21

Itispossibletoviewtheeventsthathaveoccured,onthe‘Monitor’screenor,byselectingthe‘EventLog’tabinthe‘SetupControl’page.This‘scree

Strona 22

This‘screenshot’ofthe‘EventLog’onthe‘Setup/Control’pageshowsthelast200eventsthathaveoccured,andalsoallowstheusertodownloadthe

Strona 23

SpecificationsPower Requirement100-240VAC+/-2%,50/60Hzsupplies+12VDC@<300mA(ULapprovedwallsupplyincluded.)Timed SwitchingClockaccuracy

Strona 24

GENERAL DESCRIPTIONTheR-199isamulti-contactrelaycapableofswitchingawayfromsignalAandconnectingtosignalB.Thereare4independentrel

Strona 25

FrontPanelViewRearPanelViewSectionView5

Strona 26

General InstructionsMounting:TheR-199requiresaminimumof1.75verticalinchesofspaceinastandard19”wideEIAequipmentrack.Slidetheuniti

Strona 27

APPLICATIONSGENERAL SWITCHINGControl by TimeTheR-199canbeswitchedaccordingtotimeschedulesenteredintotheR199bytheuser.Control by LANTh

Strona 28

This diagram shows, more specifically, the input and outputs connec-tions for the R199.8

Strona 29

ETHERNET INTERFACE SETUPOntheCDincludedwiththeunitisaprogramentitledNetburnerIPSetup.exeAfterensuringthattheR-199tobesetupispow

Komentarze do niniejszej Instrukcji

Brak uwag